Material specification | |
Inside diameter (mm): | 80•100•120•130•140•150•160•180•200•230•250•300•350•400 |
Inner surface | 0.5 mm nominal thickness
Quality 1.4404 (AISI 316L stainless steel) |
Surface thermal resistance m2K/W at 200°C | Without insulation = 0,00 |
Sealing ring | Profiled ring seal with three black silicone sealing lips conforming to UNI EN 14241/1 |
Roughness | 1 mm average value |
General information | |
Installation | Internal Yes
External NO it is not rain proof |
Fields of application | Pipes, chimneys, smoke ducts, flues and manifolds connected to blown air, atmospheric, condensation and pressurised boilers, type B, C appliances, fireplaces, stoves, kitchen hoods, ovens and ventilation ducts |
Permitted fuels | T200 Gas, Diesel oil, LPG, Pellets
T600 Gas, Diesel oil, LPG, Pellets and Firewood |
Conservation | In environments with a non-corrosive atmosphere |
Product warranty | As per the 99/44/EC directive |
Dangerous substances | None |
Freezing-thawing resistance | Meets UNI EN 1856-1 |
Accidental contact | Protective shields must be used when surface temperature is greater than 70°C |
Storage | Do not store the material near ferrous materials, premises must be dry and protected against the elements |
Usage limits | Do not use stainless steel flue systems for premises such as laundries, dye houses, furriers, printer’s, beauty salons or where there are halogen or chromium vapours/fumes |
Product meets the EN 1856-2 Standard | Pipe | Smoke duct |
No. of the standard | EN 1856-2 | EN 856-2 |
Temperature level | T200 | T200 |
Pressure level | P1 | P1 |
Resistance to condensation | W | W |
Resistance to corrosion | V2 | V2 |
Thickness of the inner surface | L50050 | L50050 |
Resistance to fire from inside and distance from combustible materials | O | O(30) M |
Product designation as per the EN 1856-2 standard: | Pipe | Smoke duct |
No. of the standard | EN 1856-2 | EN 1856-2 |
Temperature level | T600 | T600 |
Pressure level | N1 | N1 |
Resistance to condensation | D | D |
Resistance to corrosion | V2 | V2 |
Thickness of the inner surface | L50050 | L50050 |
Resistance to fire from inside and distance from combustible materials | G | G(600) M |
Performance required according to the designation | ||
Temperature level | T200
T600 |
working with a nominal fumes temperature at less than 200°C
working with a nominal fumes temperature at less than 600°C |
Pressure level | P1
N1 |
working with a positive and negative pressure up to 200Pa. Permitted loss less than 0.006 l/m2
working with a positive and negative pressure up to 40Pa. Permitted loss less than 2.0l/sm2 |
Resistance to condensation | W
D |
working with moist and dry fumes
working with dry fumes |
Resistance to corrosion | V2 V2 | working with Gas-Diesel oil-LPG-Pellets-Firewood |
Specification of the inner surface | L50 L50 | 0.5 mm nominal thickness |
Thickness of the inner surface | O | non resiste al fuoco da dentro |
not fire resistant from inside | G | Resistance to fire from inside |
Distance from combustible materials | (30) M
(600) M |
(30)=minimum 30mm; M= value obtained with lab test
(600)=minimum 600mm; M= value obtained with lab test |
INSTALLATION INSTRUCTIONS
- Install elements as shown by the arrow on the piece label.
- With use at T200_P1_W put the sealing ring in place on the female socket.
- The three lips of the sealing ring must be facing the inside of the pipe.
- Use some talcum powder or soap to make it easier to put the ring in place and prevent damages.
- In caso of T600_N1_D, use the product without the sealing ring.
- Once the pieces are in place, mount and tighten the locking clamp on each join.
- Please respect compression loads and the non-vertical installations.
- Avoid stagnation of condensation or soot which could be the cause of corrosion. Also avoid horizontal sections; nonetheless install the elements with the longitudinal welding facing up (3% slope).
ESSENTIAL FEATURES
Resistance to the wind load:
- Distance between wall brackets: NPD m
- Free length from the last bracket: NPD m
Compressive strength:
- Linear elements’ maximum load: 8m
- Maximum load of a straight fitting at 90°: 8m
- Maximum load of the wall chimney support: 8m
Note: these values refer to the worst conditions. For more info see (Mechanical Strength Table)
Tensile and bending strength (linear elements):
- Maximum load at traction (element connection means and chimney connections): 16m
- Non-vertical installations: max. 90°
- Non-vertical installations: distance between wall chimney supports = 2m
Traction and bending strength (non-linear elements):
- Non-vertical installations: NPD
FLUE SYSTEM MAINTENANCE
Scheduled maintenance carried out by qualified staff:
- Unless other standards/reglamentations or different agreements are reached with the user, the following maintenance schedule is advisable:
- gaseous fuels: 1 / year;
- liquid fuels: 1 / 6 months;
- solid fuels: 1 / month
- Clean the smoke duct with a soft plastic brush or sponge as well as the equipment compartment for pipe supply and ventilation, the inspection fitting and chimney and also make sure the smoke/fumes and condensates etc., are flowing freely.
SYSTEM COMPONENTS
1 M LINEAR ELEMENT
995 mm high modular component to use on vertical or sub-horizontal sections. Install elements as shown by the arrow on the piece label.
Codice | Dn | A | B |
4410 0080 | 80 | 995 | 40 |
4410 0100 | 100 | 995 | 40 |
4410 0120 | 120 | 995 | 40 |
4410 0130 | 130 | 995 | 40 |
4410 0140 | 140 | 995 | 40 |
4410 0150 | 150 | 995 | 40 |
4410 0160 | 160 | 995 | 40 |
4410 0180 | 180 | 995 | 40 |
4410 0200 | 200 | 995 | 40 |
4410 0230 | 230 | 995 | 40 |
4410 0250 | 250 | 995 | 40 |
4410 0300 | 300 | 995 | 40 |
4410 0350 | 350 | 995 | 40 |
4410 0400 | 400 | 995 | 40 |
0.5 M LINEAR ELEMENT
495 mm high modular component to use on vertical or sub-horizontal sections. Install elements as shown by the arrow on the piece label.
Codice | Dn | A | B |
4405 0080 | 80 | 495 | 40 |
4405 0100 | 100 | 495 | 40 |
4405 0120 | 120 | 495 | 40 |
4405 0130 | 130 | 495 | 40 |
4405 0140 | 140 | 495 | 40 |
4405 0150 | 150 | 495 | 40 |
4405 0160 | 160 | 495 | 40 |
4405 0180 | 180 | 495 | 40 |
4405 0200 | 200 | 495 | 40 |
4405 0230 | 230 | 495 | 40 |
4405 0250 | 250 | 495 | 40 |
4405 0300 | 300 | 495 | 40 |
4405 0350 | 350 | 495 | 40 |
4405 0400 | 400 | 495 | 40 |
0.25 M LINEAR ELEMENT
245 mm high modular component to use on vertical or sub-horizontal sections. Install elements as shown by the arrow on the piece label.
Codice | Dn | A | B |
4402 0080 | 80 | 245 | 40 |
4402 0100 | 100 | 245 | 40 |
4402 0120 | 120 | 245 | 40 |
4402 0130 | 130 | 245 | 40 |
4402 0140 | 140 | 245 | 40 |
4402 0150 | 150 | 245 | 40 |
4402 0160 | 160 | 245 | 40 |
4402 0180 | 180 | 245 | 40 |
4402 0200 | 200 | 245 | 40 |
4402 0230 | 230 | 245 | 40 |
4402 0250 | 250 | 245 | 40 |
4402 0300 | 300 | 245 | 40 |
4402 0350 | 350 | 245 | 40 |
4402 0400 | 400 | 245 | 40 |
SLIDING ELEMENT
This element is used in sub-horizontal or vertical sections where a standard linear element cannot be used because the distance is not defined. It can be used in all linear elements since it slides inside them. It should only be used for suction pressure or dry flue systems. If used in the vertical position a wall chimney support (4519) must be mounted above it.
Codice | Dn | A | B |
4499 0080 | 80 | 495 | 78 |
4499 0100 | 100 | 495 | 98 |
4499 0120 | 120 | 495 | 118 |
4499 0130 | 130 | 495 | 128 |
4499 0140 | 140 | 495 | 138 |
4499 0150 | 150 | 495 | 148 |
4499 0160 | 160 | 495 | 158 |
4499 0180 | 180 | 495 | 178 |
4499 0200 | 200 | 495 | 198 |
4499 0230 | 230 | 495 | 228 |
4499 0250 | 250 | 495 | 248 |
4499 0300 | 300 | 495 | 298 |
4499 0350 | 350 | 495 | 348 |
4499 0400 | 400 | 495 | 398 |
90° STRAIGHT FITTING – FEMALE COUPLING
With this component the duct, chimney and flue can be connected at 90 to the smoke duct °. The peculiarity of this element is that it is made by extrusion meaning the female coupling can be welded without a seam.
Codice | Dn | A | B | A/2 |
4506 0080 | 80 | 328 | 40 | 164 |
4506 0100 | 100 | 328 | 40 | 164 |
4506 0120 | 120 | 328 | 40 | 164 |
4506 0130 | 130 | 328 | 40 | 164 |
4506 0140 | 140 | 328 | 40 | 164 |
4506 0150 | 150 | 328 | 40 | 164 |
4506 0160 | 160 | 328 | 40 | 164 |
4506 0180 | 180 | 495 | 40 | 247,5 |
4506 0200 | 200 | 495 | 40 | 247,5 |
4506 0230 | 230 | 495 | 40 | 247,5 |
4506 0250 | 250 | 495 | 40 | 247,5 |
4506 0300 | 300 | 495 | 40 | 247,5 |
4506 0350 | 350 | 595 | 40 | 297,5 |
4506 0400 | 400 | 595 | 40 | 297,5 |
per innesto maschio COD 4546
90° STRAIGHT FITTING DIAM.80 REDUCTION – FEMALE COUPLING
With this component the duct, chimney and flue can be connected to the smoke duct at 90° with an 80 mm diameter. The peculiarity of this element is that it is made by extrusion meaning the female coupling can be welded without a seam.
Codice | Dn | A | B | A/2 |
4527 0080 | 80 | 328 | 40 | 164 |
4527 0100 | 100 | 328 | 40 | 164 |
4527 0120 | 120 | 328 | 40 | 164 |
4527 0130 | 130 | 328 | 40 | 164 |
4527 0140 | 140 | 328 | 40 | 164 |
4527 0150 | 150 | 328 | 40 | 164 |
4527 0160 | 160 | 328 | 40 | 164 |
4527 0180 | 180 | 328 | 40 | 164 |
4527 0200 | 200 | 328 | 40 | 164 |
4527 0230 | 230 | 328 | 40 | 164 |
4527 0250 | 250 | 328 | 40 | 164 |
4527 0300 | 300 | 328 | 40 | 164 |
4527 0350 | 350 | – | – | – |
4527 0400 | 400 | – | – | – |
for male coupling CODE 4528
135° ANGLED FITTING – MALE COUPLING
With this component the chimney and flue can be connected to the smoke duct at 135°. Due to its shape, it can be used for dry and low pressure fumes N1-D.
Codice | Dn | A | B | C | D | E |
4507 0080 | 80 | 328 | 40 | 100 | 200 | 149 |
4507 0100 | 100 | 328 | 40 | 100 | 210 | 149 |
4507 0120 | 120 | 328 | 40 | 100 | 235 | 173 |
4507 0130 | 130 | 495 | 40 | 120 | 360 | 261 |
4507 0140 | 140 | 495 | 40 | 120 | 360 | 261 |
4507 0150 | 150 | 495 | 40 | 132 | 360 | 262 |
4507 0160 | 160 | 495 | 40 | 120 | 360 | 261 |
4507 0180 | 180 | 495 | 40 | 120 | 360 | 261 |
4507 0200 | 200 | 495 | 40 | 132 | 360 | 262 |
4507 0230 | 230 | 495 | 40 | 120 | 360 | 261 |
4507 0250 | 250 | 615 | 40 | 152 | 460 | 332 |
4507 0300 | 300 | 615 | 40 | 152 | 460 | 332 |
4507 0350 | 350 | 760 | 40 | 180 | 580 | 382 |
4507 0400 | 400 | 760 | 40 | 180 | 580 | 424 |
FUNNEL FITTING
This component is used to connect square sections to round sections. It is normally used from where the fireplace starts and rectangular sections can be made.
Codice | Dn | A | B |
4122 0080 | 80 | – | – |
4122 0100 | 100 | – | – |
4122 0120 | 120 | – | – |
4122 0130 | 130 | – | – |
41220140 | 140 | – | – |
41220150 | 150 | – | – |
41220160 | 160 | – | – |
4507 0180 | 180 | 280 | 180 |
4507 0200 | 200 | 280 | 200 |
41220230 | 230 | 280 | 230 |
4507 0250 | 250 | 280 | 250 |
4507 0300 | 300 | 280 | 300 |
41220350 | 350 | 280 | 350 |
41220400 | 400 | 280 | 400 |
30° CURVE
Thanks to this component the vertical axis of the chimney, flue, pipe or smoke duct can be slanted 30°.
Codice | Dn | A | B | C |
4503 0080 | 80 | 176 | 40 | 47 |
4503 0100 | 100 | 187 | 40 | 50 |
4503 0120 | 120 | 179 | 40 | 48 |
4503 0130 | 130 | 176 | 40 | 47 |
4503 0140 | 140 | 170 | 40 | 45 |
4503 0150 | 150 | 187 | 40 | 50 |
4503 0160 | 160 | 187 | 40 | 50 |
4503 0180 | 180 | 194 | 40 | 52 |
4503 0200 | 200 | 212 | 40 | 57 |
4503 0230 | 230 | 194 | 40 | 52 |
4503 0250 | 250 | 212 | 40 | 57 |
4503 0300 | 300 | 212 | 40 | 57 |
4503 0350 | 350 | 212 | 40 | 58 |
4503 0400 | 400 | 212 | 40 | 58 |
45° CURVE
Thanks to this component the vertical axis of the chimney, flue, pipe or smoke duct can be slanted 45°.
Codice | Dn | A | B | D |
4504 0080 | 80 | 183 | 40 | 76 |
4504 0100 | 100 | 190 | 40 | 79 |
4504 0120 | 120 | 183 | 40 | 76 |
4504 0130 | 130 | 183 | 40 | 76 |
4504 0140 | 140 | 183 | 40 | 76 |
4504 0150 | 150 | 190 | 40 | 79 |
4504 0160 | 160 | 183 | 40 | 76 |
4504 0180 | 180 | 200 | 40 | 83 |
4504 0200 | 200 | 230 | 40 | 93 |
4504 0230 | 230 | 200 | 40 | 83 |
4504 0250 | 250 | 230 | 40 | 93 |
4504 0300 | 300 | 230 | 40 | 93 |
4504 0350 | 350 | 261 | 40 | 108 |
4504 0400 | 400 | 272 | 40 | 113 |
90° CURVE
The vertical axis can be slanted 90° with this component.
Codice | Dn | A | B | C |
4505 0080 | 80 | 175 | 40 | 175 |
4505 0100 | 100 | 175 | 40 | 175 |
4505 0120 | 120 | 180 | 40 | 180 |
4505 0130 | 130 | 180 | 40 | 180 |
4505 0140 | 140 | 190 | 40 | 190 |
4505 0150 | 150 | 190 | 40 | 190 |
4505 0160 | 160 | 210 | 40 | 210 |
4505 0180 | 180 | 215 | 40 | 215 |
4505 0200 | 200 | 233 | 40 | 233 |
4505 0230 | 230 | 233 | 40 | 233 |
4505 0250 | 250 | 255 | 40 | 255 |
4505 0300 | 300 | 305 | 40 | 305 |
4505 0350 | 350 | 300 | 40 | 300 |
4505 0400 | 400 | 355 | 40 | 355 |
ADJUSTABLE CURVE
With this component the vertical axis can be slanted up to 90° with respect to the vertical position.
Codice | Dn | A | B | C |
4522 0080 | 80 | 165 | 40 | 250 |
4522 0100 | 100 | 170 | 40 | 280 |
4522 0120 | 120 | 180 | 40 | 300 |
4522 0130 | 130 | 185 | 40 | 310 |
4522 0140 | 140 | 190 | 40 | 310 |
4522 0150 | 150 | 195 | 40 | 310 |
4522 0160 | 160 | 200 | 40 | 325 |
4522 0180 | 180 | 205 | 40 | 360 |
4522 0200 | 200 | 210 | 40 | 365 |
4522 0230 | 230 | – | 40 | – |
4522 0250 | 250 | 300 | 40 | 515 |
4522 0300 | 300 | 340 | 40 | 550 |
4522 0350 | 350 | – | 40 | – |
4522 0400 | 400 | – | 40 | – |
INSPECTION FITTING WITH SEALING PLUG (T200)
Necessary for cleaning and maintenance work; to be placed under the connections or as prescribed by the standard. Suitable for moist and positive pressure fumes: T200-P1-W.
Codice | Dn | A | B | C | A/2 |
4537 0080 | 80 | 328 | 40 | 80 | 164 |
4537 0100 | 100 | 328 | 40 | 100 | 164 |
4537 0120 | 120 | 328 | 40 | 120 | 164 |
4537 0130 | 130 | 328 | 40 | 130 | 164 |
4537 0140 | 140 | 328 | 40 | 140 | 164 |
4537 0150 | 150 | 328 | 40 | 150 | 164 |
4537 0160 | 160 | 328 | 40 | 160 | 164 |
4537 0180 | 180 | 495 | 40 | 180 | 247,5 |
4537 0200 | 200 | 495 | 40 | 200 | 247,5 |
4537 0230 | 230 | 495 | 40 | 200 | 247,5 |
4537 0250 | 250 | 495 | 40 | 200 | 247,5 |
4537 0300 | 300 | 495 | 40 | 200 | 247,5 |
4537 0350 | 350 | 495 | 40 | 200 | 247,5 |
4537 0400 | 400 | 495 | 40 | 200 | 247,5 |
INSPECTION FITTING WITH SEALING PLUG (T600)
Necessary for cleaning and maintenance work; to be placed under the connections or as prescribed by the standard. Suitable for dry and negative pressure fumes: T600-N1-D.
Codice | Dn | A | B | C | A/2 |
4591 0080 | 80 | 328 | 40 | 80 | 164 |
4591 0100 | 100 | 328 | 40 | 100 | 164 |
4591 0120 | 120 | 328 | 40 | 120 | 164 |
4591 0130 | 130 | 328 | 40 | 130 | 164 |
4591 0140 | 140 | 328 | 40 | 140 | 164 |
4591 0150 | 150 | 328 | 40 | 150 | 164 |
4591 0160 | 160 | 328 | 40 | 160 | 164 |
4591 0180 | 180 | 495 | 40 | 180 | 247,5 |
4591 0200 | 200 | 495 | 40 | 200 | 247,5 |
4591 0230 | 230 | 495 | 40 | 200 | 247,5 |
4591 0250 | 250 | 495 | 40 | 200 | 247,5 |
4591 0300 | 300 | 495 | 40 | 200 | 247,5 |
4591 0350 | 350 | 495 | 40 | 200 | 247,5 |
4591 0400 | 400 | 495 | 40 | 200 | 247,5 |
CONDENSATION CONTAINER WITH HERMETIC DOOR
Component for collecting condensation and/or impurities; to position at the base of the chimney/flue. It has a removable container and hermetic door.
Codice | Dn | A | B | C |
4516 0080 | 80 | – | – | – |
4516 0100 | 100 | – | – | – |
4516 0120 | 120 | 160 | 220 | 140 |
4516 0130 | 130 | 160 | 220 | 140 |
4516 0140 | 140 | 160 | 220 | 200 |
4516 0150 | 150 | 160 | 220 | 200 |
4516 0160 | 160 | 160 | 220 | 270 |
4516 0180 | 180 | 220 | 290 | 270 |
4516 0200 | 200 | 220 | 290 | 270 |
4516 0230 | 230 | 220 | 290 | 270 |
4516 0250 | 250 | 220 | 290 | 270 |
4516 0300 | 300 | 220 | 390 | 390 |
4516 0350 | 350 | – | – | – |
4516 0400 | 400 | – | – | – |
INSPECTION FITTING WITH DOOR
Necessary for cleaning and maintenance work; to be placed under the connections or as prescribed by the standard. Temperature class is T450.
Codice | Dn | A | B | C | D | E |
4514 0080 | 80 | – | – | – | – | – |
4514 0100 | 100 | – | – | – | – | – |
4514 0120 | 120 | 495 | 40 | 248 | 113 | 190 |
4514 0130 | 130 | 495 | 40 | 248 | 113 | 190 |
4514 0140 | 140 | 495 | 40 | 248 | 113 | 190 |
4514 0150 | 150 | 495 | 40 | 248 | 113 | 190 |
4514 0160 | 160 | 495 | 40 | 248 | 113 | 190 |
4514 0180 | 180 | 495 | 40 | 248 | 113 | 190 |
4514 0200 | 200 | 495 | 40 | 248 | 113 | 190 |
4514 0230 | 230 | 495 | 40 | 248 | 200 | 290 |
4514 0250 | 250 | 495 | 40 | 248 | 200 | 290 |
4514 0300 | 300 | 495 | 40 | 248 | 200 | 290 |
4514 0350 | 350 | 495 | 40 | 248 | 162 | 222 |
4514 0400 | 400 | 495 | 40 | 248 | 162 | 222 |
FUMES CONTROL FITTING (NO PYROMETER)
Component used to control the temperature of the fumes and their quality. To place above the connections for systems over 35 KW, in proximity of the end part for systems with potentials greater than 581 KW (Italian Presidential Decree 1391/70).
Codice | Dn | A | B | C | D | E |
4515 0080 | 80 | – | – | – | – | – |
4515 0100 | 100 | – | – | – | – | – |
4515 0120 | 120 | 495 | 40 | 248 | 113 | 190 |
4515 0130 | 130 | 495 | 40 | 248 | 113 | 190 |
4515 0140 | 140 | 495 | 40 | 248 | 113 | 190 |
4515 0150 | 150 | 495 | 40 | 248 | 113 | 190 |
4515 0160 | 160 | 495 | 40 | 248 | 113 | 190 |
4515 0180 | 180 | 495 | 40 | 248 | 113 | 190 |
4515 0200 | 200 | 495 | 40 | 248 | 113 | 190 |
4515 0230 | 230 | 495 | 40 | 248 | 113 | 190 |
4515 0250 | 250 | 495 | 40 | 248 | 113 | 190 |
4515 0300 | 300 | 495 | 40 | 248 | 113 | 190 |
4515 0350 | 350 | 495 | 40 | 248 | 113 | 190 |
4515 0400 | 400 | 495 | 40 | 248 | 113 | 190 |
ELEMENT WITH SCREW FOR FUMES ANALYSIS
Component used for analysing single and collective fumes systems connected to Type C appliances (UNI 10641/97).
Codice | Dn | A | B | C |
4536 0080 | 80 | 245 | 40 | 122,5 |
4536 0100 | 100 | 245 | 40 | 122,5 |
4536 0120 | 120 | 245 | 40 | 122,5 |
4536 0130 | 130 | 245 | 40 | 122,5 |
4536 0140 | 140 | 245 | 40 | 122,5 |
4536 0150 | 150 | 245 | 40 | 122,5 |
4536 0160 | 160 | 245 | 40 | 122,5 |
4536 0180 | 180 | 245 | 40 | 122,5 |
4536 0200 | 200 | 245 | 40 | 122,5 |
4536 0230 | 230 | 245 | 40 | 122,5 |
4536 0250 | 250 | 245 | 40 | 122,5 |
4536 0300 | 300 | 245 | 40 | 122,5 |
4536 0350 | 350 | 245 | 40 | 122,5 |
4536 0400 | 400 | 245 | 40 | 122,5 |
CHINESE CHIMNEY CAP
Component to place on the top; it provides sufficient protection against rain and snow.
Codice | Dn | A | B |
4117 0080 | 80 | 120 | 216 |
4117 0100 | 100 | 120 | 216 |
4117 0120 | 120 | 150 | 276 |
4117 0130 | 130 | 150 | 276 |
4117 0140 | 140 | 150 | 276 |
4117 0150 | 150 | 150 | 276 |
4117 0160 | 160 | 150 | 276 |
4117 0180 | 180 | 200 | 395 |
4117 0200 | 200 | 200 | 395 |
4117 0230 | 230 | 200 | 395 |
4117 0250 | 250 | 210 | 395 |
4117 0300 | 300 | 250 | 471 |
4117 0350 | 350 | 260 | 471 |
4117 0400 | 400 | 290 | 600 |
WINDPROOF CHIMNEY CAP
Component to place on the top; it protects against the rain, snow and wind.
Codice | Dn | A | B | C |
4518 0080 | 80 | 215 | 40 | 250 |
4518 0100 | 100 | 215 | 40 | 250 |
4518 0120 | 120 | 215 | 40 | 300 |
4518 0130 | 130 | 215 | 40 | 300 |
4518 0140 | 140 | 215 | 40 | 300 |
4518 0150 | 150 | 283 | 40 | 300 |
4518 0160 | 160 | 283 | 40 | 300 |
4518 0180 | 180 | 283 | 40 | 400 |
4518 0200 | 200 | 283 | 40 | 400 |
4518 0230 | 230 | 333 | 40 | 500 |
4518 0250 | 250 | 333 | 40 | 500 |
4518 0300 | 300 | 415 | 40 | 550 |
4518 0350 | 350 | 415 | 40 | 600 |
4518 0400 | 400 | 415 | 40 | 600 |
EAVES PLATE
Component to place at the base of the chimney; its peculiarity is that it is made by swaging a flat disk.
Moreover, the condensate discharge is made in stainless steel, ¾” thread and is welded in place.
Codice | Dn | A |
4509 0080 | 80 | 75 |
4509 0100 | 100 | 79 |
4509 0120 | 120 | 82 |
4509 0130 | 130 | 85 |
4509 0140 | 140 | 87 |
4509 0150 | 150 | 89 |
4509 0160 | 160 | 91 |
4509 0180 | 180 | 95 |
4509 0200 | 200 | 98 |
4509 0230 | 230 | 95 |
4509 0250 | 250 | 109 |
4509 0300 | 300 | 107 |
4509 0350 | 350 | 112 |
4509 0400 | 400 | 115 |
EAVES PLATE WITH SUPPORTING BASE
Component with the same characteristics as the eaves plate but this one has a supporting base that allows the chimney/flue to start from the ground.
Codice | Dn | A |
4534 0080 | 80 | 226 |
4534 0100 | 100 | 226 |
4534 0120 | 120 | 226 |
4534 0130 | 130 | 231 |
4534 0140 | 140 | 231 |
4534 0150 | 150 | 236 |
4534 0160 | 160 | 236 |
4534 0180 | 180 | 236 |
4534 0200 | 200 | 236 |
4534 0230 | 230 | 241 |
4534 0250 | 250 | 241 |
4534 0300 | 300 | 241 |
4534 0350 | 350 | 241 |
4534 0400 | 400 | 241 |
DOUBLE FEMALE SOCKET ELEMENT
Linear component characterised by two female sockets.
Codice | Dn | A |
4531 0080 | 80 | 120 |
4531 0100 | 100 | 120 |
4531 0120 | 120 | 120 |
4531 0130 | 130 | 120 |
4531 0140 | 140 | 120 |
4531 0150 | 150 | 120 |
4531 0160 | 160 | 120 |
4531 0180 | 180 | 120 |
4531 0200 | 200 | 120 |
4531 0230 | 230 | 120 |
4531 0250 | 250 | 120 |
4531 0300 | 300 | 120 |
4531 0350 | 350 | 120 |
4531 0400 | 400 | 120 |
DOUBLE MALE SOCKET ELEMENT
Linear component characterised by two male sockets.
Codice | Dn | A | B |
4529 0080 | 80 | 120 | 40 |
4529 0100 | 100 | 120 | 40 |
4529 0120 | 120 | 120 | 40 |
4529 0130 | 130 | 120 | 40 |
4529 0140 | 140 | 120 | 40 |
4529 0150 | 150 | 120 | 40 |
4529 0160 | 160 | 120 | 40 |
4529 0180 | 180 | 120 | 40 |
4529 0200 | 200 | 120 | 40 |
4529 0230 | 230 | 120 | 40 |
4529 0250 | 250 | 120 | 40 |
4529 0300 | 300 | 120 | 40 |
4529 0350 | 350 | 120 | 40 |
4529 0400 | 400 | 120 | 40 |
SEALING RING T200
Necessary for sealing the pipe, chimney, flue and smoke duct. Black colour, designation T200 (250°C test temperature) and is not available with a 400 diameter. It conforms to standard UNI EN 14241/1 T200 W2 K2.
Codice | Dn | A |
4021 0080 | 80 | 12 |
4021 0100 | 100 | 12 |
4021 0120 | 120 | 12 |
4021 0130 | 130 | 12 |
4021 0140 | 140 | 12 |
4021 0150 | 150 | 12 |
4021 0160 | 160 | 12 |
4021 0180 | 180 | 12 |
4021 0200 | 200 | 12 |
4021 0230 | 230 | 12 |
4021 0250 | 250 | 12 |
4021 0300 | 300 | 12 |
4021 0350 | 350 | 12 |
0° OUTLET ELEMENT
This component is used to connect chimneys, pipes and smoke ducts of different sections. No preparation required.
Codice | Dn | A | B | C | D |
4548 0080 | 80 | 160 | 40 | 241 | 250 |
4548 0100 | 100 | 160 | 40 | 241 | 250 |
4548 0120 | 120 | 160 | 40 | 241 | 250 |
4548 0130 | 130 | 160 | 40 | 241 | 250 |
4548 0140 | 140 | 160 | 40 | 241 | 250 |
4548 0150 | 150 | 160 | 40 | 241 | 250 |
4548 0160 | 160 | 160 | 40 | 241 | 250 |
4548 0180 | 180 | 160 | 40 | 320 | 320 |
4548 0200 | 200 | 160 | 40 | 320 | 320 |
4548 0230 | 230 | 160 | 40 | 320 | 320 |
4548 0250 | 250 | 160 | 40 | 320 | 320 |
4548 0300 | 300 | 160 | 40 | 400 | 400 |
4548 0350 | 350 | 160 | 40 | 480 | 480 |
4548 0400 | 400 | 160 | 40 | 480 | 480 |
TRUNCATED REDUCTIONS FROM LARGE FEMALE Ø TO SMALL MALE Ø
This component is necessary to support the weight of the chimney/flue. The base can be fixed to the floor allowing passage through structures.
Codice | Dn | A | B |
4526 0080 | 80 | 160 | 40 |
4526 0100 | 100 | 160 | 40 |
4526 0120 | 120 | 160 | 40 |
4526 0130 | 130 | 160 | 40 |
4526 0140 | 140 | 160 | 40 |
4526 0150 | 150 | 160 | 40 |
4526 0160 | 160 | 160 | 40 |
4526 0180 | 180 | 160 | 40 |
4526 0200 | 200 | 160 | 40 |
4526 0230 | 230 | 160 | 40 |
4526 0250 | 250 | 160 | 40 |
4526 0300 | 300 | 160 | 40 |
4526 0350 | 350 | 160 | 40 |
4526 0400 | 400 | 160 | 40 |
- Cod. 4124: Male-male version
- Cod. 4123: Female-female version
- Cod. 4524: Big male diameter – small female diameter version
CONICAL REDUCTIONS
This component is used to gradually connect chimneys, pipes and smoke ducts of different sections.
Codice | Dn | A | B |
4523 0080 | 80 | 240 | 40 |
4523 0100 | 100 | 240 | 40 |
4523 0120 | 120 | 240 | 40 |
4523 0130 | 130 | 240 | 40 |
4523 0140 | 140 | 240 | 40 |
4523 0150 | 150 | 240 | 40 |
4523 0160 | 160 | 240 | 40 |
4523 0180 | 180 | 240 | 40 |
4523 0200 | 200 | 240 | 40 |
4523 0230 | 230 | 240 | 40 |
4523 0250 | 250 | 240 | 40 |
4523 0300 | 300 | 240 | 40 |
4523 0350 | 350 | 240 | 40 |
4523 0400 | 400 | 240 | 40 |
DARK BROWN MATT DAMASK EFFECT (RAL 8017)If temperatures exceed 250° (on the outer surface) the paint could flake and come off. |
|
OUTER SURFACE FINISH IN MATT DARK BROWN (RAL 8017)If temperatures exceed 250° (on the outer surface) the paint could flake and come off. |
|
OUTER SURFACE FINISH IN BLACKIf temperatures exceed 450° (on the outer surface) the paint could flake and come off. |
|
OUTER SURFACE FINISH IN WHITE (RAL 9010)If temperatures exceed 250° (on the outer surface) the paint could flake and come off. |
MAIN FEATURES
- Made in AISI 316L BA stainless steel, 0.5 mm thick;
- Flexible for all situations;
- Quick and easy to mount;
- EN 14241-1 certified sealing ring;
- Competitive;
- Complete product range.
MAIN FEATURES
- Made in AISI 316L BA stainless steel, 0.5 mm thick;
- Flexible for all situations;
- Quick and easy to mount;
- EN 14241-1 certified sealing ring;
- Competitive;
- Complete product range.
Material specification | |
Inside diameter (mm): | 80•100•120•130•140•150•160•180•200•230•250•300•350•400 |
Inner surface | 0.5 mm nominal thickness
Quality 1.4404 (AISI 316L stainless steel) |
Surface thermal resistance m2K/W at 200°C | Without insulation = 0,00 |
Sealing ring | Profiled ring seal with three black silicone sealing lips conforming to UNI EN 14241/1 |
Roughness | 1 mm average value |
General information | |
Installation | Internal Yes
External NO it is not rain proof |
Fields of application | Pipes, chimneys, smoke ducts, flues and manifolds connected to blown air, atmospheric, condensation and pressurised boilers, type B, C appliances, fireplaces, stoves, kitchen hoods, ovens and ventilation ducts |
Permitted fuels | T200 Gas, Diesel oil, LPG, Pellets
T600 Gas, Diesel oil, LPG, Pellets and Firewood |
Conservation | In environments with a non-corrosive atmosphere |
Product warranty | As per the 99/44/EC directive |
Dangerous substances | None |
Freezing-thawing resistance | Meets UNI EN 1856-1 |
Accidental contact | Protective shields must be used when surface temperature is greater than 70°C |
Storage | Do not store the material near ferrous materials, premises must be dry and protected against the elements |
Usage limits | Do not use stainless steel flue systems for premises such as laundries, dye houses, furriers, printer’s, beauty salons or where there are halogen or chromium vapours/fumes |
Product meets the EN 1856-2 Standard | Pipe | Smoke duct |
No. of the standard | EN 1856-2 | EN 856-2 |
Temperature level | T200 | T200 |
Pressure level | P1 | P1 |
Resistance to condensation | W | W |
Resistance to corrosion | V2 | V2 |
Thickness of the inner surface | L50050 | L50050 |
Resistance to fire from inside and distance from combustible materials | O | O(30) M |
Product designation as per the EN 1856-2 standard: | Pipe | Smoke duct |
No. of the standard | EN 1856-2 | EN 1856-2 |
Temperature level | T600 | T600 |
Pressure level | N1 | N1 |
Resistance to condensation | D | D |
Resistance to corrosion | V2 | V2 |
Thickness of the inner surface | L50050 | L50050 |
Resistance to fire from inside and distance from combustible materials | G | G(600) M |
Performance required according to the designation | ||
Temperature level | T200
T600 |
working with a nominal fumes temperature at less than 200°C
working with a nominal fumes temperature at less than 600°C |
Pressure level | P1
N1 |
working with a positive and negative pressure up to 200Pa. Permitted loss less than 0.006 l/m2
working with a positive and negative pressure up to 40Pa. Permitted loss less than 2.0l/sm2 |
Resistance to condensation | W
D |
working with moist and dry fumes
working with dry fumes |
Resistance to corrosion | V2 V2 | working with Gas-Diesel oil-LPG-Pellets-Firewood |
Specification of the inner surface | L50 L50 | 0.5 mm nominal thickness |
Thickness of the inner surface | O | non resiste al fuoco da dentro |
not fire resistant from inside | G | Resistance to fire from inside |
Distance from combustible materials | (30) M
(600) M |
(30)=minimum 30mm; M= value obtained with lab test
(600)=minimum 600mm; M= value obtained with lab test |
INSTALLATION INSTRUCTIONS
- Install elements as shown by the arrow on the piece label.
- With use at T200_P1_W put the sealing ring in place on the female socket.
- The three lips of the sealing ring must be facing the inside of the pipe.
- Use some talcum powder or soap to make it easier to put the ring in place and prevent damages.
- In caso of T600_N1_D, use the product without the sealing ring.
- Once the pieces are in place, mount and tighten the locking clamp on each join.
- Please respect compression loads and the non-vertical installations.
- Avoid stagnation of condensation or soot which could be the cause of corrosion. Also avoid horizontal sections; nonetheless install the elements with the longitudinal welding facing up (3% slope).
ESSENTIAL FEATURES
Resistance to the wind load:
- Distance between wall brackets: NPD m
- Free length from the last bracket: NPD m
Compressive strength:
- Linear elements’ maximum load: 8m
- Maximum load of a straight fitting at 90°: 8m
- Maximum load of the wall chimney support: 8m
Note: these values refer to the worst conditions. For more info see (Mechanical Strength Table)
Tensile and bending strength (linear elements):
- Maximum load at traction (element connection means and chimney connections): 16m
- Non-vertical installations: max. 90°
- Non-vertical installations: distance between wall chimney supports = 2m
Traction and bending strength (non-linear elements):
- Non-vertical installations: NPD
FLUE SYSTEM MAINTENANCE
Scheduled maintenance carried out by qualified staff:
- Unless other standards/reglamentations or different agreements are reached with the user, the following maintenance schedule is advisable:
- gaseous fuels: 1 / year;
- liquid fuels: 1 / 6 months;
- solid fuels: 1 / month
- Clean the smoke duct with a soft plastic brush or sponge as well as the equipment compartment for pipe supply and ventilation, the inspection fitting and chimney and also make sure the smoke/fumes and condensates etc., are flowing freely.
SYSTEM COMPONENTS
1 M LINEAR ELEMENT
995 mm high modular component to use on vertical or sub-horizontal sections. Install elements as shown by the arrow on the piece label.
Codice | Dn | A | B |
4410 0080 | 80 | 995 | 40 |
4410 0100 | 100 | 995 | 40 |
4410 0120 | 120 | 995 | 40 |
4410 0130 | 130 | 995 | 40 |
4410 0140 | 140 | 995 | 40 |
4410 0150 | 150 | 995 | 40 |
4410 0160 | 160 | 995 | 40 |
4410 0180 | 180 | 995 | 40 |
4410 0200 | 200 | 995 | 40 |
4410 0230 | 230 | 995 | 40 |
4410 0250 | 250 | 995 | 40 |
4410 0300 | 300 | 995 | 40 |
4410 0350 | 350 | 995 | 40 |
4410 0400 | 400 | 995 | 40 |
0.5 M LINEAR ELEMENT
495 mm high modular component to use on vertical or sub-horizontal sections. Install elements as shown by the arrow on the piece label.
Codice | Dn | A | B |
4405 0080 | 80 | 495 | 40 |
4405 0100 | 100 | 495 | 40 |
4405 0120 | 120 | 495 | 40 |
4405 0130 | 130 | 495 | 40 |
4405 0140 | 140 | 495 | 40 |
4405 0150 | 150 | 495 | 40 |
4405 0160 | 160 | 495 | 40 |
4405 0180 | 180 | 495 | 40 |
4405 0200 | 200 | 495 | 40 |
4405 0230 | 230 | 495 | 40 |
4405 0250 | 250 | 495 | 40 |
4405 0300 | 300 | 495 | 40 |
4405 0350 | 350 | 495 | 40 |
4405 0400 | 400 | 495 | 40 |
0.25 M LINEAR ELEMENT
245 mm high modular component to use on vertical or sub-horizontal sections. Install elements as shown by the arrow on the piece label.
Codice | Dn | A | B |
4402 0080 | 80 | 245 | 40 |
4402 0100 | 100 | 245 | 40 |
4402 0120 | 120 | 245 | 40 |
4402 0130 | 130 | 245 | 40 |
4402 0140 | 140 | 245 | 40 |
4402 0150 | 150 | 245 | 40 |
4402 0160 | 160 | 245 | 40 |
4402 0180 | 180 | 245 | 40 |
4402 0200 | 200 | 245 | 40 |
4402 0230 | 230 | 245 | 40 |
4402 0250 | 250 | 245 | 40 |
4402 0300 | 300 | 245 | 40 |
4402 0350 | 350 | 245 | 40 |
4402 0400 | 400 | 245 | 40 |
SLIDING ELEMENT
This element is used in sub-horizontal or vertical sections where a standard linear element cannot be used because the distance is not defined. It can be used in all linear elements since it slides inside them. It should only be used for suction pressure or dry flue systems. If used in the vertical position a wall chimney support (4519) must be mounted above it.
Codice | Dn | A | B |
4499 0080 | 80 | 495 | 78 |
4499 0100 | 100 | 495 | 98 |
4499 0120 | 120 | 495 | 118 |
4499 0130 | 130 | 495 | 128 |
4499 0140 | 140 | 495 | 138 |
4499 0150 | 150 | 495 | 148 |
4499 0160 | 160 | 495 | 158 |
4499 0180 | 180 | 495 | 178 |
4499 0200 | 200 | 495 | 198 |
4499 0230 | 230 | 495 | 228 |
4499 0250 | 250 | 495 | 248 |
4499 0300 | 300 | 495 | 298 |
4499 0350 | 350 | 495 | 348 |
4499 0400 | 400 | 495 | 398 |
90° STRAIGHT FITTING – FEMALE COUPLING
With this component the duct, chimney and flue can be connected at 90 to the smoke duct °. The peculiarity of this element is that it is made by extrusion meaning the female coupling can be welded without a seam.
Codice | Dn | A | B | A/2 |
4506 0080 | 80 | 328 | 40 | 164 |
4506 0100 | 100 | 328 | 40 | 164 |
4506 0120 | 120 | 328 | 40 | 164 |
4506 0130 | 130 | 328 | 40 | 164 |
4506 0140 | 140 | 328 | 40 | 164 |
4506 0150 | 150 | 328 | 40 | 164 |
4506 0160 | 160 | 328 | 40 | 164 |
4506 0180 | 180 | 495 | 40 | 247,5 |
4506 0200 | 200 | 495 | 40 | 247,5 |
4506 0230 | 230 | 495 | 40 | 247,5 |
4506 0250 | 250 | 495 | 40 | 247,5 |
4506 0300 | 300 | 495 | 40 | 247,5 |
4506 0350 | 350 | 595 | 40 | 297,5 |
4506 0400 | 400 | 595 | 40 | 297,5 |
per innesto maschio COD 4546
90° STRAIGHT FITTING DIAM.80 REDUCTION – FEMALE COUPLING
With this component the duct, chimney and flue can be connected to the smoke duct at 90° with an 80 mm diameter. The peculiarity of this element is that it is made by extrusion meaning the female coupling can be welded without a seam.
Codice | Dn | A | B | A/2 |
4527 0080 | 80 | 328 | 40 | 164 |
4527 0100 | 100 | 328 | 40 | 164 |
4527 0120 | 120 | 328 | 40 | 164 |
4527 0130 | 130 | 328 | 40 | 164 |
4527 0140 | 140 | 328 | 40 | 164 |
4527 0150 | 150 | 328 | 40 | 164 |
4527 0160 | 160 | 328 | 40 | 164 |
4527 0180 | 180 | 328 | 40 | 164 |
4527 0200 | 200 | 328 | 40 | 164 |
4527 0230 | 230 | 328 | 40 | 164 |
4527 0250 | 250 | 328 | 40 | 164 |
4527 0300 | 300 | 328 | 40 | 164 |
4527 0350 | 350 | – | – | – |
4527 0400 | 400 | – | – | – |
for male coupling CODE 4528
135° ANGLED FITTING – MALE COUPLING
With this component the chimney and flue can be connected to the smoke duct at 135°. Due to its shape, it can be used for dry and low pressure fumes N1-D.
Codice | Dn | A | B | C | D | E |
4507 0080 | 80 | 328 | 40 | 100 | 200 | 149 |
4507 0100 | 100 | 328 | 40 | 100 | 210 | 149 |
4507 0120 | 120 | 328 | 40 | 100 | 235 | 173 |
4507 0130 | 130 | 495 | 40 | 120 | 360 | 261 |
4507 0140 | 140 | 495 | 40 | 120 | 360 | 261 |
4507 0150 | 150 | 495 | 40 | 132 | 360 | 262 |
4507 0160 | 160 | 495 | 40 | 120 | 360 | 261 |
4507 0180 | 180 | 495 | 40 | 120 | 360 | 261 |
4507 0200 | 200 | 495 | 40 | 132 | 360 | 262 |
4507 0230 | 230 | 495 | 40 | 120 | 360 | 261 |
4507 0250 | 250 | 615 | 40 | 152 | 460 | 332 |
4507 0300 | 300 | 615 | 40 | 152 | 460 | 332 |
4507 0350 | 350 | 760 | 40 | 180 | 580 | 382 |
4507 0400 | 400 | 760 | 40 | 180 | 580 | 424 |
FUNNEL FITTING
This component is used to connect square sections to round sections. It is normally used from where the fireplace starts and rectangular sections can be made.
Codice | Dn | A | B |
4122 0080 | 80 | – | – |
4122 0100 | 100 | – | – |
4122 0120 | 120 | – | – |
4122 0130 | 130 | – | – |
41220140 | 140 | – | – |
41220150 | 150 | – | – |
41220160 | 160 | – | – |
4507 0180 | 180 | 280 | 180 |
4507 0200 | 200 | 280 | 200 |
41220230 | 230 | 280 | 230 |
4507 0250 | 250 | 280 | 250 |
4507 0300 | 300 | 280 | 300 |
41220350 | 350 | 280 | 350 |
41220400 | 400 | 280 | 400 |
30° CURVE
Thanks to this component the vertical axis of the chimney, flue, pipe or smoke duct can be slanted 30°.
Codice | Dn | A | B | C |
4503 0080 | 80 | 176 | 40 | 47 |
4503 0100 | 100 | 187 | 40 | 50 |
4503 0120 | 120 | 179 | 40 | 48 |
4503 0130 | 130 | 176 | 40 | 47 |
4503 0140 | 140 | 170 | 40 | 45 |
4503 0150 | 150 | 187 | 40 | 50 |
4503 0160 | 160 | 187 | 40 | 50 |
4503 0180 | 180 | 194 | 40 | 52 |
4503 0200 | 200 | 212 | 40 | 57 |
4503 0230 | 230 | 194 | 40 | 52 |
4503 0250 | 250 | 212 | 40 | 57 |
4503 0300 | 300 | 212 | 40 | 57 |
4503 0350 | 350 | 212 | 40 | 58 |
4503 0400 | 400 | 212 | 40 | 58 |
45° CURVE
Thanks to this component the vertical axis of the chimney, flue, pipe or smoke duct can be slanted 45°.
Codice | Dn | A | B | D |
4504 0080 | 80 | 183 | 40 | 76 |
4504 0100 | 100 | 190 | 40 | 79 |
4504 0120 | 120 | 183 | 40 | 76 |
4504 0130 | 130 | 183 | 40 | 76 |
4504 0140 | 140 | 183 | 40 | 76 |
4504 0150 | 150 | 190 | 40 | 79 |
4504 0160 | 160 | 183 | 40 | 76 |
4504 0180 | 180 | 200 | 40 | 83 |
4504 0200 | 200 | 230 | 40 | 93 |
4504 0230 | 230 | 200 | 40 | 83 |
4504 0250 | 250 | 230 | 40 | 93 |
4504 0300 | 300 | 230 | 40 | 93 |
4504 0350 | 350 | 261 | 40 | 108 |
4504 0400 | 400 | 272 | 40 | 113 |
90° CURVE
The vertical axis can be slanted 90° with this component.
Codice | Dn | A | B | C |
4505 0080 | 80 | 175 | 40 | 175 |
4505 0100 | 100 | 175 | 40 | 175 |
4505 0120 | 120 | 180 | 40 | 180 |
4505 0130 | 130 | 180 | 40 | 180 |
4505 0140 | 140 | 190 | 40 | 190 |
4505 0150 | 150 | 190 | 40 | 190 |
4505 0160 | 160 | 210 | 40 | 210 |
4505 0180 | 180 | 215 | 40 | 215 |
4505 0200 | 200 | 233 | 40 | 233 |
4505 0230 | 230 | 233 | 40 | 233 |
4505 0250 | 250 | 255 | 40 | 255 |
4505 0300 | 300 | 305 | 40 | 305 |
4505 0350 | 350 | 300 | 40 | 300 |
4505 0400 | 400 | 355 | 40 | 355 |
ADJUSTABLE CURVE
With this component the vertical axis can be slanted up to 90° with respect to the vertical position.
Codice | Dn | A | B | C |
4522 0080 | 80 | 165 | 40 | 250 |
4522 0100 | 100 | 170 | 40 | 280 |
4522 0120 | 120 | 180 | 40 | 300 |
4522 0130 | 130 | 185 | 40 | 310 |
4522 0140 | 140 | 190 | 40 | 310 |
4522 0150 | 150 | 195 | 40 | 310 |
4522 0160 | 160 | 200 | 40 | 325 |
4522 0180 | 180 | 205 | 40 | 360 |
4522 0200 | 200 | 210 | 40 | 365 |
4522 0230 | 230 | – | 40 | – |
4522 0250 | 250 | 300 | 40 | 515 |
4522 0300 | 300 | 340 | 40 | 550 |
4522 0350 | 350 | – | 40 | – |
4522 0400 | 400 | – | 40 | – |
INSPECTION FITTING WITH SEALING PLUG (T200)
Necessary for cleaning and maintenance work; to be placed under the connections or as prescribed by the standard. Suitable for moist and positive pressure fumes: T200-P1-W.
Codice | Dn | A | B | C | A/2 |
4537 0080 | 80 | 328 | 40 | 80 | 164 |
4537 0100 | 100 | 328 | 40 | 100 | 164 |
4537 0120 | 120 | 328 | 40 | 120 | 164 |
4537 0130 | 130 | 328 | 40 | 130 | 164 |
4537 0140 | 140 | 328 | 40 | 140 | 164 |
4537 0150 | 150 | 328 | 40 | 150 | 164 |
4537 0160 | 160 | 328 | 40 | 160 | 164 |
4537 0180 | 180 | 495 | 40 | 180 | 247,5 |
4537 0200 | 200 | 495 | 40 | 200 | 247,5 |
4537 0230 | 230 | 495 | 40 | 200 | 247,5 |
4537 0250 | 250 | 495 | 40 | 200 | 247,5 |
4537 0300 | 300 | 495 | 40 | 200 | 247,5 |
4537 0350 | 350 | 495 | 40 | 200 | 247,5 |
4537 0400 | 400 | 495 | 40 | 200 | 247,5 |
INSPECTION FITTING WITH SEALING PLUG (T600)
Necessary for cleaning and maintenance work; to be placed under the connections or as prescribed by the standard. Suitable for dry and negative pressure fumes: T600-N1-D.
Codice | Dn | A | B | C | A/2 |
4591 0080 | 80 | 328 | 40 | 80 | 164 |
4591 0100 | 100 | 328 | 40 | 100 | 164 |
4591 0120 | 120 | 328 | 40 | 120 | 164 |
4591 0130 | 130 | 328 | 40 | 130 | 164 |
4591 0140 | 140 | 328 | 40 | 140 | 164 |
4591 0150 | 150 | 328 | 40 | 150 | 164 |
4591 0160 | 160 | 328 | 40 | 160 | 164 |
4591 0180 | 180 | 495 | 40 | 180 | 247,5 |
4591 0200 | 200 | 495 | 40 | 200 | 247,5 |
4591 0230 | 230 | 495 | 40 | 200 | 247,5 |
4591 0250 | 250 | 495 | 40 | 200 | 247,5 |
4591 0300 | 300 | 495 | 40 | 200 | 247,5 |
4591 0350 | 350 | 495 | 40 | 200 | 247,5 |
4591 0400 | 400 | 495 | 40 | 200 | 247,5 |
CONDENSATION CONTAINER WITH HERMETIC DOOR
Component for collecting condensation and/or impurities; to position at the base of the chimney/flue. It has a removable container and hermetic door.
Codice | Dn | A | B | C |
4516 0080 | 80 | – | – | – |
4516 0100 | 100 | – | – | – |
4516 0120 | 120 | 160 | 220 | 140 |
4516 0130 | 130 | 160 | 220 | 140 |
4516 0140 | 140 | 160 | 220 | 200 |
4516 0150 | 150 | 160 | 220 | 200 |
4516 0160 | 160 | 160 | 220 | 270 |
4516 0180 | 180 | 220 | 290 | 270 |
4516 0200 | 200 | 220 | 290 | 270 |
4516 0230 | 230 | 220 | 290 | 270 |
4516 0250 | 250 | 220 | 290 | 270 |
4516 0300 | 300 | 220 | 390 | 390 |
4516 0350 | 350 | – | – | – |
4516 0400 | 400 | – | – | – |
INSPECTION FITTING WITH DOOR
Necessary for cleaning and maintenance work; to be placed under the connections or as prescribed by the standard. Temperature class is T450.
Codice | Dn | A | B | C | D | E |
4514 0080 | 80 | – | – | – | – | – |
4514 0100 | 100 | – | – | – | – | – |
4514 0120 | 120 | 495 | 40 | 248 | 113 | 190 |
4514 0130 | 130 | 495 | 40 | 248 | 113 | 190 |
4514 0140 | 140 | 495 | 40 | 248 | 113 | 190 |
4514 0150 | 150 | 495 | 40 | 248 | 113 | 190 |
4514 0160 | 160 | 495 | 40 | 248 | 113 | 190 |
4514 0180 | 180 | 495 | 40 | 248 | 113 | 190 |
4514 0200 | 200 | 495 | 40 | 248 | 113 | 190 |
4514 0230 | 230 | 495 | 40 | 248 | 200 | 290 |
4514 0250 | 250 | 495 | 40 | 248 | 200 | 290 |
4514 0300 | 300 | 495 | 40 | 248 | 200 | 290 |
4514 0350 | 350 | 495 | 40 | 248 | 162 | 222 |
4514 0400 | 400 | 495 | 40 | 248 | 162 | 222 |
FUMES CONTROL FITTING (NO PYROMETER)
Component used to control the temperature of the fumes and their quality. To place above the connections for systems over 35 KW, in proximity of the end part for systems with potentials greater than 581 KW (Italian Presidential Decree 1391/70).
Codice | Dn | A | B | C | D | E |
4515 0080 | 80 | – | – | – | – | – |
4515 0100 | 100 | – | – | – | – | – |
4515 0120 | 120 | 495 | 40 | 248 | 113 | 190 |
4515 0130 | 130 | 495 | 40 | 248 | 113 | 190 |
4515 0140 | 140 | 495 | 40 | 248 | 113 | 190 |
4515 0150 | 150 | 495 | 40 | 248 | 113 | 190 |
4515 0160 | 160 | 495 | 40 | 248 | 113 | 190 |
4515 0180 | 180 | 495 | 40 | 248 | 113 | 190 |
4515 0200 | 200 | 495 | 40 | 248 | 113 | 190 |
4515 0230 | 230 | 495 | 40 | 248 | 113 | 190 |
4515 0250 | 250 | 495 | 40 | 248 | 113 | 190 |
4515 0300 | 300 | 495 | 40 | 248 | 113 | 190 |
4515 0350 | 350 | 495 | 40 | 248 | 113 | 190 |
4515 0400 | 400 | 495 | 40 | 248 | 113 | 190 |
ELEMENT WITH SCREW FOR FUMES ANALYSIS
Component used for analysing single and collective fumes systems connected to Type C appliances (UNI 10641/97).
Codice | Dn | A | B | C |
4536 0080 | 80 | 245 | 40 | 122,5 |
4536 0100 | 100 | 245 | 40 | 122,5 |
4536 0120 | 120 | 245 | 40 | 122,5 |
4536 0130 | 130 | 245 | 40 | 122,5 |
4536 0140 | 140 | 245 | 40 | 122,5 |
4536 0150 | 150 | 245 | 40 | 122,5 |
4536 0160 | 160 | 245 | 40 | 122,5 |
4536 0180 | 180 | 245 | 40 | 122,5 |
4536 0200 | 200 | 245 | 40 | 122,5 |
4536 0230 | 230 | 245 | 40 | 122,5 |
4536 0250 | 250 | 245 | 40 | 122,5 |
4536 0300 | 300 | 245 | 40 | 122,5 |
4536 0350 | 350 | 245 | 40 | 122,5 |
4536 0400 | 400 | 245 | 40 | 122,5 |
CHINESE CHIMNEY CAP
Component to place on the top; it provides sufficient protection against rain and snow.
Codice | Dn | A | B |
4117 0080 | 80 | 120 | 216 |
4117 0100 | 100 | 120 | 216 |
4117 0120 | 120 | 150 | 276 |
4117 0130 | 130 | 150 | 276 |
4117 0140 | 140 | 150 | 276 |
4117 0150 | 150 | 150 | 276 |
4117 0160 | 160 | 150 | 276 |
4117 0180 | 180 | 200 | 395 |
4117 0200 | 200 | 200 | 395 |
4117 0230 | 230 | 200 | 395 |
4117 0250 | 250 | 210 | 395 |
4117 0300 | 300 | 250 | 471 |
4117 0350 | 350 | 260 | 471 |
4117 0400 | 400 | 290 | 600 |
WINDPROOF CHIMNEY CAP
Component to place on the top; it protects against the rain, snow and wind.
Codice | Dn | A | B | C |
4518 0080 | 80 | 215 | 40 | 250 |
4518 0100 | 100 | 215 | 40 | 250 |
4518 0120 | 120 | 215 | 40 | 300 |
4518 0130 | 130 | 215 | 40 | 300 |
4518 0140 | 140 | 215 | 40 | 300 |
4518 0150 | 150 | 283 | 40 | 300 |
4518 0160 | 160 | 283 | 40 | 300 |
4518 0180 | 180 | 283 | 40 | 400 |
4518 0200 | 200 | 283 | 40 | 400 |
4518 0230 | 230 | 333 | 40 | 500 |
4518 0250 | 250 | 333 | 40 | 500 |
4518 0300 | 300 | 415 | 40 | 550 |
4518 0350 | 350 | 415 | 40 | 600 |
4518 0400 | 400 | 415 | 40 | 600 |
EAVES PLATE
Component to place at the base of the chimney; its peculiarity is that it is made by swaging a flat disk.
Moreover, the condensate discharge is made in stainless steel, ¾” thread and is welded in place.
Codice | Dn | A |
4509 0080 | 80 | 75 |
4509 0100 | 100 | 79 |
4509 0120 | 120 | 82 |
4509 0130 | 130 | 85 |
4509 0140 | 140 | 87 |
4509 0150 | 150 | 89 |
4509 0160 | 160 | 91 |
4509 0180 | 180 | 95 |
4509 0200 | 200 | 98 |
4509 0230 | 230 | 95 |
4509 0250 | 250 | 109 |
4509 0300 | 300 | 107 |
4509 0350 | 350 | 112 |
4509 0400 | 400 | 115 |
EAVES PLATE WITH SUPPORTING BASE
Component with the same characteristics as the eaves plate but this one has a supporting base that allows the chimney/flue to start from the ground.
Codice | Dn | A |
4534 0080 | 80 | 226 |
4534 0100 | 100 | 226 |
4534 0120 | 120 | 226 |
4534 0130 | 130 | 231 |
4534 0140 | 140 | 231 |
4534 0150 | 150 | 236 |
4534 0160 | 160 | 236 |
4534 0180 | 180 | 236 |
4534 0200 | 200 | 236 |
4534 0230 | 230 | 241 |
4534 0250 | 250 | 241 |
4534 0300 | 300 | 241 |
4534 0350 | 350 | 241 |
4534 0400 | 400 | 241 |
DOUBLE FEMALE SOCKET ELEMENT
Linear component characterised by two female sockets.
Codice | Dn | A |
4531 0080 | 80 | 120 |
4531 0100 | 100 | 120 |
4531 0120 | 120 | 120 |
4531 0130 | 130 | 120 |
4531 0140 | 140 | 120 |
4531 0150 | 150 | 120 |
4531 0160 | 160 | 120 |
4531 0180 | 180 | 120 |
4531 0200 | 200 | 120 |
4531 0230 | 230 | 120 |
4531 0250 | 250 | 120 |
4531 0300 | 300 | 120 |
4531 0350 | 350 | 120 |
4531 0400 | 400 | 120 |
DOUBLE MALE SOCKET ELEMENT
Linear component characterised by two male sockets.
Codice | Dn | A | B |
4529 0080 | 80 | 120 | 40 |
4529 0100 | 100 | 120 | 40 |
4529 0120 | 120 | 120 | 40 |
4529 0130 | 130 | 120 | 40 |
4529 0140 | 140 | 120 | 40 |
4529 0150 | 150 | 120 | 40 |
4529 0160 | 160 | 120 | 40 |
4529 0180 | 180 | 120 | 40 |
4529 0200 | 200 | 120 | 40 |
4529 0230 | 230 | 120 | 40 |
4529 0250 | 250 | 120 | 40 |
4529 0300 | 300 | 120 | 40 |
4529 0350 | 350 | 120 | 40 |
4529 0400 | 400 | 120 | 40 |
SEALING RING T200
Necessary for sealing the pipe, chimney, flue and smoke duct. Black colour, designation T200 (250°C test temperature) and is not available with a 400 diameter. It conforms to standard UNI EN 14241/1 T200 W2 K2.
Codice | Dn | A |
4021 0080 | 80 | 12 |
4021 0100 | 100 | 12 |
4021 0120 | 120 | 12 |
4021 0130 | 130 | 12 |
4021 0140 | 140 | 12 |
4021 0150 | 150 | 12 |
4021 0160 | 160 | 12 |
4021 0180 | 180 | 12 |
4021 0200 | 200 | 12 |
4021 0230 | 230 | 12 |
4021 0250 | 250 | 12 |
4021 0300 | 300 | 12 |
4021 0350 | 350 | 12 |
0° OUTLET ELEMENT
This component is used to connect chimneys, pipes and smoke ducts of different sections. No preparation required.
Codice | Dn | A | B | C | D |
4548 0080 | 80 | 160 | 40 | 241 | 250 |
4548 0100 | 100 | 160 | 40 | 241 | 250 |
4548 0120 | 120 | 160 | 40 | 241 | 250 |
4548 0130 | 130 | 160 | 40 | 241 | 250 |
4548 0140 | 140 | 160 | 40 | 241 | 250 |
4548 0150 | 150 | 160 | 40 | 241 | 250 |
4548 0160 | 160 | 160 | 40 | 241 | 250 |
4548 0180 | 180 | 160 | 40 | 320 | 320 |
4548 0200 | 200 | 160 | 40 | 320 | 320 |
4548 0230 | 230 | 160 | 40 | 320 | 320 |
4548 0250 | 250 | 160 | 40 | 320 | 320 |
4548 0300 | 300 | 160 | 40 | 400 | 400 |
4548 0350 | 350 | 160 | 40 | 480 | 480 |
4548 0400 | 400 | 160 | 40 | 480 | 480 |
TRUNCATED REDUCTIONS FROM LARGE FEMALE Ø TO SMALL MALE Ø
This component is necessary to support the weight of the chimney/flue. The base can be fixed to the floor allowing passage through structures.
Codice | Dn | A | B |
4526 0080 | 80 | 160 | 40 |
4526 0100 | 100 | 160 | 40 |
4526 0120 | 120 | 160 | 40 |
4526 0130 | 130 | 160 | 40 |
4526 0140 | 140 | 160 | 40 |
4526 0150 | 150 | 160 | 40 |
4526 0160 | 160 | 160 | 40 |
4526 0180 | 180 | 160 | 40 |
4526 0200 | 200 | 160 | 40 |
4526 0230 | 230 | 160 | 40 |
4526 0250 | 250 | 160 | 40 |
4526 0300 | 300 | 160 | 40 |
4526 0350 | 350 | 160 | 40 |
4526 0400 | 400 | 160 | 40 |
- Cod. 4124: Male-male version
- Cod. 4123: Female-female version
- Cod. 4524: Big male diameter – small female diameter version
CONICAL REDUCTIONS
This component is used to gradually connect chimneys, pipes and smoke ducts of different sections.
Codice | Dn | A | B |
4523 0080 | 80 | 240 | 40 |
4523 0100 | 100 | 240 | 40 |
4523 0120 | 120 | 240 | 40 |
4523 0130 | 130 | 240 | 40 |
4523 0140 | 140 | 240 | 40 |
4523 0150 | 150 | 240 | 40 |
4523 0160 | 160 | 240 | 40 |
4523 0180 | 180 | 240 | 40 |
4523 0200 | 200 | 240 | 40 |
4523 0230 | 230 | 240 | 40 |
4523 0250 | 250 | 240 | 40 |
4523 0300 | 300 | 240 | 40 |
4523 0350 | 350 | 240 | 40 |
4523 0400 | 400 | 240 | 40 |
DARK BROWN MATT DAMASK EFFECT (RAL 8017)If temperatures exceed 250° (on the outer surface) the paint could flake and come off. |
|
OUTER SURFACE FINISH IN MATT DARK BROWN (RAL 8017)If temperatures exceed 250° (on the outer surface) the paint could flake and come off. |
|
OUTER SURFACE FINISH IN BLACKIf temperatures exceed 450° (on the outer surface) the paint could flake and come off. |
|
OUTER SURFACE FINISH IN WHITE (RAL 9010)If temperatures exceed 250° (on the outer surface) the paint could flake and come off. |